- 1 -User’s Manual35mm Film ScannerLS-1000Contents1. Overview1.1 Features1.2 Operating Environment2. Before Operation2.1 Inspection2.2 Accessories2.3
- 10 -1. OverviewThank you for purchasing the Nikon 35mm Film ScannerLS-1000. This manual describes the procedures for unpacking,setting up, and conn
- 11 -1.2 Operating EnvironmentLeave extra space around and above the unit to ensure smoothoperation. Please refer to the drawing below for the amoun
- 12 -2. Before Operation2.1 InspectionInspect the package to see whether any damage has occurredduring shipment. If there is any damage to the packa
- 13 -2.3 OptionsThe LS-1000 has an optional auto slide feeder, the SF-100,which enables automatic feeding of mounted 35mm slides.2.4 Notes on Use• Do
- 14 -2.5 Cleaning the UnitWhen carrying out routine maintenance and cleaning, ensurethat no volatile liquids such as alcohol, benzine, or thinner com
- 15 -3. Parts Identification3.1 Main UnitFront panelFilm Loading Slot:The film holder is inserted here.Option Connector:The SF-100 slide autofeeder i
- 16 -Rear panelSCSI Connector:For SCSI cable connection. (No differencebetween IN and OUT.)SCSI ID Switch: Sets the SCSI ID number. Numbers 0 to 7ar
- 17 -3.2 Display LEDThe display LED is located on the front panel and shows thescanner status.Steady illumination:Lights when power is supplied (READ
- 18 -3.3 Strip Film Holder FH-2This strip film holder can be used with a strip of film containingup to six images.Lower holderUpper holderLower holde
- 19 -4. Connecting the LS-10004.1 Before ConnectionBefore connecting the cables, confirm that all devices, includingthe computer system and the LS-10
- 2 -Cautions• The reproduction of all or part of this manual without ourpermission is prohibited.• The information contained in this manual is subjec
- 20 -• The power source must be grounded.• If possible, try to use an independent electric outlet. If the unit isconnected to an outlet to which an
- 21 -4.3 Connecting the SCSI CableBefore connecting the SCSI cable, confirm that all SCSI devices,including the computer system, have been turned off
- 22 -If the unit is the only connected SCSI device, or if the unit isconnected at the end of the SCSI chain, attach a terminator(terminal resistance)
- 23 -SCSI Chain Connection with Other DevicesIf the LS-1000 is connected at the end of the SCSIchain;• Connect the 50-pin full pitch connector of the
- 24 -Remarks• The maximum number of SCSI devices that can beconnected to one computer is eight. In the case of a hostcomputer with a built-in SCSI h
- 25 -4.4 Setting the SCSI IDThe SCSI ID for the LS-1000 is set at “5” when the unit isshipped. If other SCSI devices are connected to yourcomputer,
- 26 -5. Operation5.1 Turning on the PowerTurn the LS-1000 on first, the other SCSI devices next, and thehost computer last.After turning the power on
- 27 -5.2 Film InsertionThe LS-1000 can scan different types of 35mm positive/negativemonochrome/color images. In addition, it can scan a film stripo
- 28 -The standard orientation of a mounted portrait or landscapeslide is shown below. (If the top and bottom are reversed,modification is possible by
- 29 -Insertion of Strip filmInsert the strip film into the attached film holder FH-2, and theninsert the holder into the film slot of the front panel
- 3 -Federal Communications Commission (FCC)Radio Frequency Interference StatementThis equipment has been tested and found to comply with thelimits fo
- 30 -Step 3Align each image of the strip film with an aperture in the lowerholder.Step 4Close the upper holder, aligning both ends of the upper holde
- 31 -Step 5Align the image to be read with either of the two apertures inthe silver-colored adaptor.Insert the film holder in the film slot of the fr
- 32 -Step 6Insert the film holder until it touches the back inside wall of theunit and the mark comes in alignment with the edge of film slot.Remarks
- 33 -6. TroubleshootingIf something unusual should occur, please check the followingitems before you assume that there is a unit failure. For morede
- 34 -Appendix: SpecificationsFilm used: 35mm film (color/monochrome, negative/positive)Mounted slides (3.0mm or less and 1.1mm ormore in thickness)St
- 35 -IndexAAC inlet 16Accessories 12CConnecting 19–25connecting the SCSI cable 21connecting the terminator 22preparation for 19to other devices
- 36 -EC DECLARATION OF CONFORMITYWeName: Nikon UK LimitedAddress: Nikon House, 380 Richmond Road, Kingston, Surrey KT25PR, UKdeclare that the product
- 4 -Cautions for SafetyIn order to use the LS-1000 safely and correctly, and to preventproblems, pay careful attention to the following points:• Use
- 5 -• Do not pull or bent the SCSI cable. This can cause the cableto break.• Do not connect or remove peripheral equipment while thepower switch is
- 6 -If You Notice Anything AbnormalIf unusual noise, odor or smoke occurs, switch the Unit offimmediately and disconnect the power cord and the SCSI
- 7 -• The Unit is exposed to direct sunlight.• The atmosphere is excessively dusty.• The Unit may be subjected to excessive vibration or physicalshoc
- 8 -• The Unit is exposed to noise from other equipment nearby.Leave suffucient space around the unit to ensure that theventilation slots are not blo
- 9 -Notice concerning prohibition of copying orreproductionNote that simply being in possession of material which has beencopied or reproduced by mea