Nikon UPS Bedienungsanleitung Seite 22

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 29
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 21
UPS/400 . . . an IBM AS/400 UPS power monitoring system . . .
22
SELW: This job is in a select wait. More information on the select() function is in the Sockets
APIs chapter in the System API Reference, SC41-4801.
SRQ: The job is the suspended half of a system request job pair.
SVFA: The job is waiting for completion of a Save File operation in the activity level.
SVFW: The job is waiting for completion of a Save File operation.
TAPA: The job is waiting for completion of an I/O operation to a tape device in the activity level.
TAPW: The job is waiting for completion of an I
/
O operation to a tape device.
TIMA: The job is waiting, in the activity level, for a time interval to end.
TIMW: The job is waiting for a time interval to end.
DISPLAY ACTIVITY LOG
The Display Messages display shows messages sent to a message queue. Among the parameters shown
are message queue name, delivery mode, and break handling program.
For specific information about messages, put the cursor on the message you want information about and
press the Help key. An additional message information display will then be shown.
QUEUE: The name of the message queue that is being shown.
LIBRARY: The name of the library that contains the message queue being shown.
SEVERITY: A two digit value ranging from 00 through 99. The higher the value, the more severe or
important the condition. The value is used when the delivery mode is *BREAK or *NOTIFY. Only
messages equal to or greater than the value defined here will cause the break or notification of the
message to occur.
PROGRAM: The following values may be shown:
*DSPMSG: When a message arrives for an interactive job with break delivery, the message is
displayed.
A program name: The name of the program that is called when a message arrives if the
message queue is in *BREAK delivery and the message is equal to or greater than the severity
value shown on the display.
LIBRARY: The name of the library that contains the break message handling program.
Display Messages
System: PBSEO4
Queue . . . . . . . : UPSLOG Program . . . . . . :*DSPMSG
Library . . . . .: UPS400 Library . . . . . . :
Severity . . . . . . : 00 Delivery . . . . . . : *HOLD
Type reply (if required), press Enter.
ATTENTION: POWER RESTORED The AS/400 has been switched back to utility power at
09/27/98 20:29:29.
UPS/400 detected a temporary power loss at 09/27/98 20:30:58.
UPS/400 detected a power loss at 20:52. Estimated time to power down is 20 minutes.
ATTENTION: POWER RESTORED The AS/400 has been switched back to utility power at
09/27/98 20:53:45.
UPS/400 detected power loss at 20:54. Estimated time to power down is 19 minutes.