Preparation of Housing Before the Dive
Make Common or Required Camera Settings:
Prior to inserting camera in housing, it is recommended that Menu option settings be
made according to the preferences of the user. Most of these choices are ones that will
remain unchanged for most of the time while diving, and therefore it will be more
convenient and less time consuming to make the settings prior to diving.
Mount Housing Port:
Clean & Lubricate Port O-ring [for Port O-ring only]
1. In order to properly maintain the Port O-ring you must periodically
remove port O-ring from channel using only your fingers.
2. Push and lift the O-ring from its channel.
3. Do NOT use any sharp instruments, such as knives or dental picks, to
remove O-ring. You may accidentally cut the O-ring causing a potential
leakage.
4. Inspect the O-ring visually and by feel for any cuts, nicks, flat spots,
stretching, or any debris, such as sand, dirt, lint, hair, or other matter that
could compromise the integrity of the seal.
5. Clean O-ring by soaking in fresh water until all debris is removed.
6. Dry O-ring with a soft clean cloth. Be careful it does not leave any lint on
the O-ring.
7. Lubricate the O-ring with the supplied silicone grease. Do not over-grease
the O-ring. It only requires enough grease to allow it to slip into place and
make a seal. It should be slippery and shiny but without any abundance or
build-up of grease. A teardrop amount is usually sufficient for proper
lubrication.
8. Inspect the O-ring channel for any debris or foreign matter that could
damage the O-ring or cause it to lose its seal.
9. Clean the O-ring channel using a damp cloth or Q-tip. Be careful not to
leave any lint behind.
10. Replace the O-ring in the channel by lifting it over the end of the port until
it sits in its channel. Be sure the O-ring is not twisted or deformed and out
of position in any way.
11. Mount the port on the housing body by aligning the threads on the end of
the port with the mount on the housing and screwing clockwise until it is
FULLY screwed in place.