If the unit is the only connected SCSI device, or if the unit is connected at
the end of the SCSI chain, attach a terminator (terminal resistance) to the
other SCSI connector. At this point, remove the terminator of the other
SCSI device that has been placed between them. The terminator is not
needed when the unit is connected between other SCSI devices.
When SCSI devices are connected, connect them so as not to make a loop,
and attach terminators to both ends of the SCSI chain. Since the terminator
is built into the host computer in most cases, the host computer should be at
the end of the SCSI chain. The operation manuals of some notebook
computers require a terminator to be attached outside the computer; please
refer to the operation manual for the computer to which the unit is con-
nected.
Note: The SCSI cable used for SCSI connection should be of high-imped-
ance type.